28 MDS 4710/9710 I/O Guide MDS 05-3305A01, Rev. D
Using the SNR command causes the DIAG. port to enter an update mode,
and the SNR is updated and redisplayed every two seconds. The SNR
continuously updates until the key is pressed.
SREV
Software/Firmware
Revision Level
This command displays the software revision level of the transceiver
firmware.
STAT
Alarm Status This command displays the current alarm status of the transceiver.
If no alarms exist, the message
NO ALARMS PRESENT appears at the top
of the HHT display.
If an alarm does exist, a two-digit code (00–31) is displayed and the
alarm is identified as “Major” or “Minor.” A brief description of the
alarm code is also provided.
If more than one alarm exists, the word
MORE appears at the bottom of
the screen and additional alarms are viewed by pressing the
key. Detailed descriptions of event codes are provided in Table 11 on
Page 31.
TEMP
Internal
Temperature
This command displays the internal temperature of the transceiver in
degrees Celsius.
TOT [1-255, ON, OFF]
TX Timeout-Timer This command sets or displays the transmitter Time-out Timer value
(1–255 seconds), as well as the timer status (
ON or OFF). If the timer is
on, and the radio remains keyed for a longer duration than the
TOT value,
the transmitter is automatically unkeyed.
When this happens, the radio must be commanded back to an unkeyed
state before a new keying command is accepted. The default timer value
is 30 seconds.
TX [xxx.xxxx]
TX Frequency This command selects or displays the radio’s transmit frequency in
MHz. The frequency step size is 6.25 kHz.
If the customer frequency is not programmed at the factory, a default
frequency is programmed in the radio near the center of the frequency
band.
ENTER
ENTER